All problem comparisons · Campaign
Equilibrium Sphere: Euler and ADER2
Reference: diffusion-limit analytic reference. Steady diffusion solution for a Gaussian emitter. Finite-flux nonlinear M1 and quadrature errors can produce a reference-error floor.
Coupled ADER2 accuracy remains under investigation. A completed run or a small difference does not establish uniform second-order accuracy.
Revision 6 validation limits. Streaming-wave temporal-order thresholds failed at limiter transitions even with resolved references. Optically thick radiation temporal probes remain unresolved under the unchanged 1e-12 measurement guard. Strict stiff coupled temporal tests have not been rerun for revision 6 and remain an open limitation.
Level 2
Euler (first order): complete results, parameters and reference discussion
Coupled ADER2: complete results, parameters and reference discussion
matched. No other refinement level or physical time is substituted for a missing partner.

Matched profile coordinates and values (CSV)
ADER2 minus Euler: slice discrepancy
| Field | Units | L₁ | L₂ | L∞ |
|---|---|---|---|---|
| Radiation energy density | erg/cm^3 | 1.011927e-05 | 2.440502e-05 | 1.440835e-04 |
| Radiation flux x | erg/(cm^2 s) | 7.754557e+04 | 1.627591e+05 | 1.245258e+06 |
| Radiation flux y | erg/(cm^2 s) | 7.754557e+04 | 1.627591e+05 | 1.245258e+06 |
| Radiation flux z | erg/(cm^2 s) | 2.811047e+04 | 5.144538e+04 | 2.981943e+05 |
Euler (first order) versus diffusion-limit analytic reference
Area-weighted errors on this method’s original leaf slice.
| Field | Units | L₁ | L₂ | L∞ |
|---|---|---|---|---|
| Radiation energy density | erg/cm^3 | 4.883502e-05 | 1.102998e-04 | 6.424667e-04 |
| Radiation flux x | erg/(cm^2 s) | 1.051779e+06 | 2.570489e+06 | 1.630999e+07 |
| Radiation flux y | erg/(cm^2 s) | 1.051779e+06 | 2.570489e+06 | 1.630999e+07 |
| Radiation flux z | erg/(cm^2 s) | 1.240354e+06 | 2.653502e+06 | 1.630999e+07 |
Solver-reported full-volume reference norms
| Field | Units | L₁ | L₂ | L∞ |
|---|---|---|---|---|
| Radiation energy density | erg/cm^3 | 2.019307e-05 | 5.151584e-05 | 6.424667e-04 |
| Radiation flux x | erg/(cm^2 s) | 2.596979e+05 | 9.097040e+05 | 1.630999e+07 |
| Radiation flux y | erg/(cm^2 s) | 2.596979e+05 | 9.097040e+05 | 1.630999e+07 |
| Radiation flux z | erg/(cm^2 s) | 2.596979e+05 | 9.097040e+05 | 1.630999e+07 |
Source slice CSV · Run metadata
Coupled ADER2 versus diffusion-limit analytic reference
Area-weighted errors on this method’s original leaf slice.
| Field | Units | L₁ | L₂ | L∞ |
|---|---|---|---|---|
| Radiation energy density | erg/cm^3 | 3.904556e-05 | 8.779870e-05 | 5.082125e-04 |
| Radiation flux x | erg/(cm^2 s) | 9.792466e+05 | 2.460068e+06 | 1.601179e+07 |
| Radiation flux y | erg/(cm^2 s) | 9.792466e+05 | 2.460068e+06 | 1.601179e+07 |
| Radiation flux z | erg/(cm^2 s) | 1.212244e+06 | 2.603727e+06 | 1.601179e+07 |
Solver-reported full-volume reference norms
| Field | Units | L₁ | L₂ | L∞ |
|---|---|---|---|---|
| Radiation energy density | erg/cm^3 | 1.593405e-05 | 4.090040e-05 | 5.082125e-04 |
| Radiation flux x | erg/(cm^2 s) | 2.350431e+05 | 8.708244e+05 | 1.601179e+07 |
| Radiation flux y | erg/(cm^2 s) | 2.350431e+05 | 8.708244e+05 | 1.601179e+07 |
| Radiation flux z | erg/(cm^2 s) | 2.350431e+05 | 8.708244e+05 | 1.601179e+07 |
Level 3
Euler (first order): pending.
Coupled ADER2: pending.
Level 4
Euler (first order): pending.
Coupled ADER2: pending.
How these comparisons are measured
All field values use the saved units (CGS for the seven original problems; normalized units for Marshak). The central profiles share x coordinates and the positive row adjacent to y = z = 0. Adaptive leaf-cell averages are prolonged as constants onto the finest common Cartesian x-y partition, with no extrapolation or time interpolation. Different leaf sizes may average different z extents adjacent to the plane. The plotted curves therefore represent the saved finite-volume slices.
Slice L₁ is mean absolute difference, L₂ is root-mean-square difference, and L∞ is maximum absolute difference, with area weighting. These are two-dimensional slice diagnostics. The separately labeled solver norms cover the full volume.
Each method uses its own saved cell-average reference where supplied; finer meshes can change the sampled reference.